Products Description

✅ Durable & Reusable Design
Built with a strong aluminum frame and replaceable non-woven fabric media, ensuring long service life.
✅ High Dust Holding Capacity
Efficiently captures large particles such as dust, lint, and pollen to prolong the life of downstream filters.
✅ Corrosion-Resistant Frame
The lightweight anodized aluminum frame resists rust and performs well in high-humidity environments.
✅ Washable & Replaceable Media
The non-woven fabric media can be washed and replaced, reducing both maintenance frequency and operational cost.
✅ Versatile Application
Ideal for HVAC systems, cleanrooms, and industrial ventilation as a primary filtration stage.
What Makes This Filter Different?
This product should not be selected as a normal disposable G4 pleated filter.
Its main value is the reusable frame and replaceable pad structure.
For many AHU maintenance projects, the metal holding frame is still in good condition, but the filter media becomes loaded with dust. Replacing the whole panel each time may increase storage volume, waste handling and replacement cost. With this model, the project team can keep the aluminum frame and replace only the G4 filter pad when required.
This makes it suitable for:
•AHU retrofit projects where the existing filter track size must be matched
•Commercial building maintenance teams that replace pre-filters regularly
•HVAC contractors who want to reduce bulky replacement stock
•Projects where a stronger frame is preferred over cardboard filters
•Systems where coarse dust protection is required before bag, box or HEPA filters
Parameters Details
| Item | Data / Options |
|---|---|
| Product Name | Aluminum Frame G4 Panel Filter |
| Filter Class (EN 779) | G4 coarse filter (approx. 90% @ 5.0 μm, gravimetric method) |
| Frame Material | Anodized aluminium as standard; galvanized steel frame available on request |
| Filter Media | Synthetic non-woven fabric (replaceable pad) |
| Media Support | Metal mesh or perforated sheet support, depending on model |
| Initial Resistance | Typically 45–80 Pa at rated airflow, depending on size and depth |
| Recommended Final Resistance | Up to 250 Pa, in line with EN 779 guidance for G-class pre-filters |
| Standard Depths | 21 mm, 25 mm, 46 mm |
| Standard Sizes | Multiple standard sizes available; non-standard sizes can be customised |
| Operating Temperature | Suitable for typical HVAC operating temperatures |
| Application Position | Primary / coarse pre-filter stage in HVAC and industrial ventilation systems |

Company and Product Advantages
20+ Years of Manufacturing Excellence: Decades of experience in filter production
15+ Years of Global Trade: Established international customer base
Factory Capacity: Over 6,500 square meters of manufacturing space
Quality Standards: Compliance with ISO, CE, and industry-specific certification
Environmental Commitment: Sustainable production practices
Custom Solutions: Tailored to meet specific client specifications

Maintenance Logic: Replace the Pad, Keep the Frame
The main purpose of this model is to separate the filter frame from the filter media.
During routine maintenance, the service team removes the loaded G4 pad and installs a new pad into the same aluminum frame. This can reduce the number of bulky panel filters stored on site and makes repeated maintenance easier for building operators.
Replacement should be based on one or more of the following conditions:
•Pressure drop reaches the maintenance limit defined by the project
•Dust loading is visibly heavy
•Airflow through the filter section becomes unstable
•The filter pad is damaged, deformed or contaminated
•The planned maintenance cycle has been reached
We do not recommend treating the non-woven pad as a permanent washable component. Light cleaning practices may vary by site, but for reliable filtration performance and hygiene control, pad replacement is the safer maintenance method.
Certificates
Our Certificate
✅ CE Certified for safe and compliant manufacturing

✅ RoHS Compliant for eco-friendly product standards

✅ ISO 9001 Quality Management Certification
Global Exhibitions
Trade Shows & Global Reach
We have been a consistent exhibitor at the Canton Fair for over 10 years, connecting with global buyers and expanding our market presence. As a regular participant in renowned international exhibitions such as ISH Frankfurt, AHR Expo USA, and other HVAC and cleanroom technology expos, we continuously stay aligned with the latest industry innovations and global standards.
Through these trade platforms, we have developed strong and lasting business relationships with clients in Europe, Southeast Asia, the Middle East, and North America, supplying to both OEM and branded customers. Our growing global footprint reflects our commitment to product excellence, customer trust, and long-term collaboration.

Typical Applications
Central air conditioning systems – as a G4 primary filter in AHUs and packaged units
.
Fresh air handling units and air supply systems – for first-stage filtration of outdoor air
Return air boxes and fan coil units – to control coarse dust load in recirculated air
Commercial buildings – offices, shopping malls, hotels, schools and public facilities
Light industrial and electronics workshops – as pre-filtration in front of higher-grade filters
Hospitals and healthcare buildings – in non-critical areas or as upstream pre-filters for advanced filtration stages
For specialised industrial environments, we can advise on the suitability of this G4 panel filter as part of a multi-stage filtration solution.
Ordering & Customisation
To specify an Aluminum Frame G4 Panel Filter for your project and avoid any mismatch on site, please share a few basic details so our engineer can select or design the right model for you:
Filter length × width × depth – in mm or inches, including any space limitations inside the AHU frame, filter track, or fan coil box. If you already have a drawing or an old filter, you can simply mark the overall size and we will follow it.
Frame material – aluminium or galvanized steel, and whether you need a standard frame, reinforced frame, or special thickness for high-air-volume units. You can also indicate if you require corners, handles, or mounting holes.
Filter class / efficiency – normally G4 for this type of pre-filter. If you are matching an existing system, you can send us the current label (e.g. G4 / MERV 7–8 or ISO coarse 60%) and we will keep the same performance level.
Installation quantity and application – for example, how many pieces are used as AHU pre-filters, fresh-air intake filters, or fan coil filters in one project, and your expected replacement interval (monthly, quarterly, etc.). This helps us design a cost-effective solution and suggest packing and shipment options.

On top of the basic data, you may also tell us your preferred airflow direction, gasket type, header design, and packaging requirements.
We support custom sizes, OEM / ODM branding and private label packaging, including printing your logo, item code, and barcodes on the frame and cartons. Our engineers can work directly from your CAD drawings, specification sheets, or from an existing sample filter, ensuring that the new panels drop into your current frames and deliver the same or better performance without modification on site.
Packaging & Shippiing

Filters and replacement pads can be packed separately according to project needs.
For large orders, we can support carton packing, pallet packing, mixed shipments with other filter types, project labels, item codes and barcode labels. If the project requires scheduled replacement stock, we can help separate the packing by building, floor, AHU number or filter list.
Available packing support includes:
•Export cartons
•Pallet protection
•Frame corner protection
•Replacement pad bundle packing
•OEM labels and carton marks
•Project filter list matching
•Mixed loading with other HVAC filters
Our history

fAQ
faq
Lorem ipsum dolor sit amet consectetur adipisicing elit.
Q1: Can the Non-woven Fabric media be replaced separately?
A: Yes, the media is replaceable and washable, which makes the filter reusable and cost-effective.
Q2: How often should the aluminum frame G4 panel filter be cleaned?
A: Typically every 1–3 months, depending on the dust load and application environment.
Q3: Can I request custom sizes or branding?
A: Absolutely. We support OEM/ODM services and can produce filters based on your exact specifications.
Q4: What is the MOQ (Minimum Order Quantity)?
A: For standard sizes, MOQ is low. For customized designs, MOQ may vary-please contact us for details.
Hot Tags: aluminum frame g4 panel filter, China aluminum frame g4 panel filter manufacturers, suppliers, factory, pre water filter price, 20x24x4, 20x35x2 pleated filter, perfect pleat air filters, perfect pleat filters, 16x24x2 filters





